Principles Of Cleanroom Engineering

Jul 15, 2026 Leave a message

Turbulent Flow Cleanrooms: The main characteristic of turbulent flow cleanrooms is that the cross-section of the airflow from the inlet to the outlet (from the supply air vent to the return air vent) is variable. The cleanroom cross-section is much larger than the supply air vent cross-section, thus preventing the formation of a uniform airflow across the entire room or the entire working area. Therefore, the streamlines after the supply air vent have large or increasingly larger angles with each other, and a very small radius of curvature. The airflow cannot flow in a single direction within the room; it will collide with each other, resulting in backflow and vortices. This determines that the flow pattern of a turbulent flow cleanroom is essentially: abrupt flow; non-uniform flow.

 

This is a more accurate and comprehensive description of turbulent flow cleanrooms than using the term "turbulent flow." Turbulence is mainly determined by the Reynolds number, meaning it is primarily affected by flow velocity. However, if a high-efficiency filter is used for top-supply airflow, even at extremely low velocities, the aforementioned results will still occur because it is an abrupt and non-uniform flow. Therefore, in this case, there is not only mixing between flow layers due to turbulent flow, but also mixing caused by large backflows and vortices throughout the entire room.

 

Unidirectional Flow Cleanrooms Unidirectional flow cleanrooms generally come in two types: horizontal flow and vertical flow. In a horizontal flow system, airflow moves from one wall to another. In a vertical flow system, airflow moves from the ceiling to the floor. Unidirectional flow is used for applications requiring lower concentrations of suspended particles or microorganisms. This type of cleanroom was previously called a "laminar flow" cleanroom. The names unidirectional and laminar flow describe the airflow pattern: airflow moves in one direction (either vertical or horizontal) and flows through the entire space at a uniform speed typically 0.3 m/s to 0.5 m/s (60 ft/min to 100 ft/min). High-efficiency particulate air (HEPA) filters fill the cleanroom ceiling, supplying air into the room. The airflow acts like an air piston, flowing downwards through the room, carrying away contaminants, and then exiting from the floor. After mixing with some fresh outside air, it recirculates back to the HEPA filters. Suspended contaminants generated by personnel and processes are immediately removed by this airflow, whereas turbulent flow ventilation systems utilize mixing and dilution principles. In an empty room without any obstructions, unidirectional airflow can quickly remove contaminants using much lower air velocities than previously mentioned. However, in an operating room, machines and people moving around them obstruct airflow. Obstructions can turn unidirectional airflow into turbulence, creating air pockets around the obstruction. Human activity can also cause unidirectional airflow to become turbulent. In these turbulent flows, due to lower air velocities, the air is less diluted, resulting in higher contaminant concentrations. Therefore, air velocities must be maintained in the range of 0.3 m/s to 0.5 m/s (60 ft/min to 100 ft/min) to allow interrupted unidirectional airflow to be quickly restored and to adequately dilute contaminants in the turbulent zone around the obstruction. Air velocity accurately represents unidirectional airflow because higher velocities result in a cleaner room. Air changes per hour, however, is related to room volume, such as ceiling height, and is therefore unsuitable for representing unidirectional airflow. The air volume in a unidirectional airflow room is many times (10 to 100 times) that in a turbulent airflow room.